Chapter 6 Operating Instructions
CLV490 Bar Code Scanner
6-28 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Operation
Explanation Internal object tracking
Internal object tracking can be used in autofocus mode with "Differential background and
tracking" mode or with event-controlled focus position switchover (e.g. by means of height-
control photoelectric switches at switching inputs "IN 0" to "IN 3"). If the reading pulse is
started via an external sensor, fast debouncing (5 ms) is used for the "Sensor" switching
input irrespective of the parameter settings. The CLV490 receives the signals from the
incremental encoder via switching input "IN 4". At a constant conveyor speed, the increment
can be triggered via an internal timer increment (100 Hz) (set the value for "Path per
increment encoder pulse" to 0), which means that an encoder does not need to be
connected to IN 4.
With object tracking, the reading field length corresponds to the distance in conveying
direction between the sensor for starting the reading pulse and the parameterized object
release point (see Fig. 3-5, Page 3-9). The focus release point is before the object release
point. The CLV490 uses the internal object management system and its object list to track
the objects passing through the reading field, whereby the object istance measurement
enables objects to be detected and the corresponding focus positions in the focus list to be
assigned. The increment management system continuously locates the current position of
the objects in the reading field in the conveying direction. The focus list acts as a circular
buffer, whereby the oldest entry determines the current focus position. If the CLV490
calculates that the end of an object being conveyed through the reading field has passed
the parameterized focus release point, the CLV490 switches to the next focus position and
deletes the object from the focus list. The reading result for an object is not output until the
object has left the object release point.
1. Parameterize internal object
tracking
contd.
Ö DEVICE CONFIGURATION tab
Ö ASSIGNMENT OF INPUTS section
Ö IN 4
Conveyor increment
Note:
Connect external incremental encoder to "IN 4" switching input!
2. Define scanner position
referred to the reading field
Ö DEVICE CONFIGURATION tab
Ö SCANNER POSITIONS PARAMETERS button
Ö ANGLES section
Angles: alpha, beta and gamma
Ö COORDINATES section
x-, y- and z-coordinates
3. Teach-in background
(optional)
Ö Menu CLV490
Ö DEVICE FUNCTIONS
Ö Background
–Teach-in
Check taught-in background:
Ö READING CONFIGURATION tab
Ö AUTOFOCUS section
–S
HOW BACKGROUND button
Display actual background profile:
Ö Menu CLV490
Ö BACKGROUND ANALYSIS
Action Settings in CLV-Setup
Table 6-12: Guide: Parameterzing internal object tracking (contd.)