Operating Instructions Chapter 10
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-59
Appendix
To set the background, switch to the L
IMIT
V
ALUES
tab in the same dialog window (
Fig.
10-47
). The background is formed using the autofocus area’s terminating planes. The
CLV registers the altered reading distances in this area only.
Autofocus limitation: min: 600 mm; max: 1400 mm
Autofocus space: Right edge of conveyor (Y1): 50 mm
(Limiting levels Left edge of conveyor (Y2): 550 mm
from feed level) Level of conveyor (Z1): 50 mm
Maximum scanning height (Z2): 800 mm
Fig. 10-46: Parameterization example: "Edit Auto Focus/Adjustments" dialog window
Fig. 10-47: Parameterization example: "Edit Auto Focus/Limits" dialog window