Operating Instructions Chapter 5
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-5
Electrical installation
With two open cable ends, no. 2 020 981
with one 9-pin D Sub cable connector and one open end, no. 2 020308
Connecting the CLV with external parameter memory
a) CLV without heater:
Connection Modules: AMV/S 60, AMV 30-071, BMV 10
Cover the terminals on the CLV with the connector cover (parameter memory)
no. 2 020 307. Connect the plug/socket on the cables ("Host/Term" and " I/O" con-
nections) with the appropriate connections on the AMV/S or BMV 10.
Connection Module: BMS 20.
Cover the terminals on the CLVs with the connector cover (parameter memory)
no. 2 020 308. Connect the 9-pin plug ("Host/Term" connection) to the socket on the
BMS 20. Connect the wires of the free cable end ( "I/O" terminal) to the terminal strips
in the BMS 20.
Recommendation Use the external parameter memory no. 2 020 981 (open cable ends) for connecting the
device to non-Sick Power packs/wiring configurations.
b) CLV with heater:
Connection Module: AMV 100/200
AMV 100: Cover the terminals on the CLV with the connector cover (parameter
memory) no. 2 021 689, labeled "SCANNER". Connect the other connector covers,
labeled "HOST", to the corresponding connections on the AMV 100.
AMV 200: see AMV 100, proceed in the same way with the second CLV.
5.2.6 Connections/cables for the IP 65 connector cover
(connection to AMV 100/200 or BMV 10)
The connector cover (optional accessory) with 15-pin D Sub HD plug connections is used
to cover the terminals on the CLV so that the enclosure rating IP 65 is provided.
The connector cover is prefabricated with two cables, each of 3 m in length, and is available
with two different cable ends:
With one additional connector cover at the other end (pins assignment identical to that
of the CLV terminals), no. 2 021 298
With two open cable ends, no. 2 021 267
CLV with heater:
Both connector cover variants can be used with temperatures up to max. –50
°
C if the CLV
is stationary and the cables are not moved. If the cables are moved due to changes in the
position of the CLV, the temperature must not drop below max. –40
°
C.
Recommendation Use the external parameter memory no. 2 020 267 (open cable ends) for connecting the
device to non-Sick Power packs/wiring configurations.