Operating Instructions Chapter 6
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-29
Operation
Parameterizing reading trigger in the CLV490:
Action Settings in CLV-Setup
Parameterize reading trigger:
one external sensor
Ö DEVICE CONFIGURATION tab
Start:
Ö READING TRIGGER SOURCE section
– Sensor Input (Active High) or
– Sensor Input (Active Low)
Ö READING TRIGGER PARAMETERS button
Ö DEBOUNCING SENSOR section
–Fast
Ö FIRST TRIGGER SENSOR section
– Edge or
– Level
Stop: generated by object release point
Output of reading result referred to beginning of reading
interval:
Ö DEVICE CONFIGURATION tab
Ö TRACKING PARAMETERS button
Ö RELEASE POINTS Section
– Object release point/End of reading field/Output data
Note:
Connect the external sensor to "Sensor“ switching input!
Parameterize reading trigger:
command strings
Ö DEVICE CONFIGURATION tab
Start:
Ö READING TRIGGER SOURCE section
– Serial interface
Stop: generated by object release point
Output of reading result referred to beginning of reading
interval:
Ö DEVICE CONFIGURATION tab
Ö TRACKING PARAMETERS button
Ö RELEASE POINTS Section
– Object release point/End of reading field/Output data
Trigger characters:
Ö SERIAL INTERFACE section
– Standard Trigger or
– Single character
Ö Using single character: start and stop characters
Ö Echo on/off
Table 6-13: Guide: Parameterizing the reading mode for tracking mode in stand-alone configuration