Chapter 8 Operating Instructions
CLV490 Bar Code Scanner
8-16 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Troubleshooting
1. The "Read Result" LED default setting:
Good Read) does not light up at the end
of the reading pulse:
– continued –
The bar code is tilted excessively with
respect to the scan line.
The reading angles at which the bar code
appears to the CLV490 are too large.
Bar code in total reflection zone
Evaluation criteria for bar code
incorrect.
Bar code quality inadequate.
In the "CLV-Setup" program: choose the
CODE CONFIGURATION tab, DECODER section:
choose SMART decoder.
Download all changes to CLV490!
In the "CLV-Setup" program: choose the
CODE CONFIGURATION tab, DECODER sec-
tion: choose Standard decoder.
Download temporarily to CLV490!
Start P
ERCENTAGE EVALUATION, choose
DISTANCE CONFIGURATION. Monitor read-
ing quality (reading quality > 70 %!). If
necessary, realign CLV490 and/or re-
configure distance configuration. If ok,
choose SMART D
ECODER. Download to
CLV490.
Optimize CLV490 alignment (scan line
should strike the bar code at a skew of
approx. 15°). Use the "CLV-Setup" pro-
gram to check the quality of the read.
Start PERCENTAGE EVALUATION. See
Chapter 6.5.2 Percentage evaluation,
Page 6-41
In "CLV-Setup" program: choose the
CODE CONFIGURATION tab, SYMBOLOGIES
section. Enable all code types (except
Pharmacode), set code lengths to F
REE.
Download temporarily to CLV490!
Start P
ERCENTAGE EVALUATION. Code type
and length are displayed in the reading
result. Enable recorded code type in the
C
ODES section and disable all other
types. Enter the code length under FIXED
on the code type tab. Download to
CLV490!
Check: sufficient blank zones present?
Print contrast adequate? Specified print
tolerances exceeded?
In the "CLV-Setup" program: choose
R
EADING CONFIGURATION tab, READING PARA-
METERS section, START/STOP RATIO: is Auto
selected?
Perform read with reference code.
2. The CLV490 is not transferring any rea-
ding results to the host
Reading pulse is not functioning
correctly.
Wiring fault in data connection.
Voltage level incorrect.
Host interface in CLV490 parameterized
incorrectly.
See Chapter 8.5.2 Malfunctions in Read-
ing mode: reading trigger errors,
Page 8-10
Check wiring as shown in Fig. 5-3,
Page 5-20
Measure voltages
In "CLV-Setup" program: choose HOST
I
NTERFACE tab, DATA FORMAT section. Are
the interface type (hardware) and data
format correct? Check settings in INTER-
FACE PROTOCOL section.
Malfunction Possible cause Remedy
Table 8-8: Troubleshooting: result output errors in Reading mode (CLV490 in stand-alone configuration) (contd.)