Chapter 10 Operating Instructions
CLV490 Bar Code Scanner
10-2 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Appendix
10.2.2 Overview of diagrams
Line scanner
Line scanner with oscillating mirror
CLV490-Type Resolution Scanning method Diagram Page
CLV490-0010/-0011 Standard density Line scanner Reading field height/resolution as a function of reading distance 10-3
CLV490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/40° 10-4
CLV490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/56° 10-5
CLV490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.50 mm/40° 10-6
CLV490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.50 mm/56° 10-7
CLV490-0010/-0011 Standard density Line scanner Characteristics field scanning frequency 10-8
CLV490-2010/-2011 High density Line scanner Reading field height/resolution as a function of reading distance 10-16
CLV490-2010/-2011 High density Line scanner Min. and max. reading distance (DOF) for 0.25 mm/40° 10-17
CLV490-2010/-2011 High density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/40° 10-18
CLV490-2010/-2011 High density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/56° 10-19
CLV490-2010/-2011 High density Line scanner Characteristics field scanning frequency 10-20
CLV490-6010/-6011 Low density Line scanner Reading field height/Tilt as a function of reading distance for
0.5 mm
10-27
CLV490-6010/-6011 Low density Line scanner Min. and max. reading distance (DOF) for 0.5 mm/40° 10-28
CLV490-6010/-6011 Low density Line scanner Min. and max. reading distance (DOF) for 0.5 mm/60° 10-29
CLV490-6010/-6011 Low density Line scanner Characteristics field scanning frequency 10-30
Table 10-2: Overview of specification diagrams for the line scanner
CLV490-Type Resolution Scanning method Diagram Page
CLV490-1010/-1011 Standard density L.s. with osci. mirror Reading field height/resolution as a function of reading
distance
10-9
CLV490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40° 10-10
CLV490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50° 10-11
CLV490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/40° 10-12
CLV490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/50° 10-13
CLV490-1010/-1011 Standard density L.s. with osci. mirror Characteristics field scanning frequency 10-14
CLV490-1010/-1011 Standard density L.s. with osci. mirror Deflection range 10-15
CLV490-3010/-3011 High density L.s. with osci. mirror Reading field height/resolution as a function of reading
distance
10-21
CLV490-3010/-3011 High density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.25 mm/40° 10-22
CLV490-3010/-3011 High density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40° 10-23
CLV490-3010/-3011 High density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50° 10-24
CLV490-3010/-3011 High density L.s. with osci. mirror Characteristics field scanning frequency 10-25
CLV490-3010/-3011 High density L.s. with osci. mirror Deflection range 10-26
CLV490-7010/-7011 Low density L.s. with osci. mirror Reading field height/Tilt as a function of reading distance for
0.5 mm
10-31
CLV490-7010/-7011 Low density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/40° 10-28
CLV490-7010/-7011 Low density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/50° 10-29
CLV490-7010/-7011 Low density L.s. with osci. mirror Characteristics field scanning frequency 10-32
CLV490-7010/-7011 Low density L.s. with osci. mirror Deflection range 10-33
Table 10-3: Overview of specification diagrams for the line scanner with oscillating mirror