Chapter 8 Operating Instructions
CLV490 Bar Code Scanner
8-18 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Troubleshooting
8.5.4 Malfunctions in Reading mode: errors in the result status output
¾ Check whether the "Device Ready" LED lights up.
If the LED does not light, see Table 8-5, Page 8-9 .
Malfunction Possible cause Remedy
The switching outputs
–"Result 1"
(default setting: Device Ready)
–"Result 2"
(default setting: Good Read)
–"Result 3"
(default setting: No Read)
–"Result 4"
(default setting: Match 1)
are not outputting any pulses.
The event associated with the assigned
function for outputting the result status of
the read does not occur in the reading
operation.
Incorrect switching mode parameterized
in the CLV490.
Not applicable.
In the "CLV-Setup" program: choose the
D
EVICE CONFIGURATION tab. Click the RE-
SULT OUTPUT PARAMETERS button.
Are the outputs set to "No Invert Out-
put"? Change if necessary.
Download to CLV490!
Table 8-10: Troubleshooting: errors in the result status output in Reading mode
Przeglądanie stron 159