Chapter 10 Operating Instructions
CLV490 Bar Code Scanner
10-36 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Appendix
10.3.2 Installation and electrical connection
The pin assignments/wire colors for the connection cables of the parameter memory are
shown in the following tables:
Parameter memory no. 2030023: Table 5-5, Page 5-8
Parameter memory no. 2020307: Table 5-6 and Table 5-7, Page 5-9
Parameter memory no. 2033126/no. 2033127: Table 5-8 and Table 5-9, Page 5-10
Parameter memory no. 2030065/no. 2031034: Table 5-10 and Table 5-11,
Page 5-11
Parameter memory no. 2020981: Table 5-15 and Table 5-16, Page 5-14
Parameter memory no. 2021267: Table 5-17 and Table 5-18, Page 5-15
¾ Mount the parameter memory on the CLV490 as shown in Chapter 5.5.3 Connecting the
supply voltage, Page 5-18 and connect the cables to the CBD420 or CDM490 Connec-
tion Module or to the non-SICK power supply.
10.3.3 Operation
The parameter memory in the connector cover connected to the CLV490 is accessed
using the selected CLV490 start option
after the parameters have been downloaded to the CLV490 with the permanent stora-
ge function and the S
TART WITH EXTERNAL PARAMETERS option
The start option is set at the bottom right of the D
EVICE CONFIGURATION tab as shown in
Fig. 10-32 (grey frame). The S
TART WITH EXTERNAL PARAMETERS option is selected by default.
Start with internal parameters
When it starts, the CLV490 loads the internal parameter set to its RAM.
The "Device Ready" LED lights up constantly.
Since the data is stored permanently, it is not lost when the device is switched off.
Fig. 10-33: CLV-Setup: "Device configuration" tab with the CLV490 start options