Chapter 10 Operating Instructions
CLV490 Bar Code Scanner
10-70 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Appendix
The auxiliary interface then operates temporarily in "Auxiliary input" mode (until the CLV
is switched off).
Entering the bar code using the Terminal Emulator function in CLV-Setup
1. Click on the toolbar.
The Terminal Emulator is launched.
The CLV490 is in Reading mode.
2. Click the E
XTENDED radio button in the TERMINAL MODE section.
The start and stop characters used by the Terminal Emulator are displayed at the top
of the screen, on the left and right of the text input field.
Fig. 10-57 shows the Terminal Emulator window in extended mode.
3. Use the drop-down lists to set the start and stop characters to NUL.
4. Enter the data content of the bar code (character string) on the keyboard.
Use the backspace key to correct any input errors.
The data content must not contain control characters.
5. Press the [RETURN] or [ENTER] key.
The CLV490 then interprets all further characters as a new data string.
CLV-Setup sends the character string to the CLV490 and deletes the entry in the text
field. The CLV490 does not send an echo.
6. Once the active reading pulse has ended, the CLV490 sends the data received from
the PC to the host via the host interface.
Fig. 10-57: CLV-Setup: auxiliary input via the Terminal Emulator