Operating Instructions Chapter 6
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-31
Operation
Parameterizing reading trigger in the CLV490:
Parameterizing slave mode in the CLV490:
Note When in slave mode, the CLV490 receives the trigger signals for the reading pulse (start and
stop) from the OTC400 via the CAN bus along with (depending on the parameter settings)
the distance information required for focus position switchover/autofocus. The distance
information can be generated, for example, by the OTC400 by means of height-control
photoelectric switches or can originate from another CLV490, which forwards its distance
measurements.
The CLV490 sends the reading result (bar code contents) to the OTC400 via the bus as
soon as the bar code(s) have been successfully read. The OTC400 compiles the results
received from all the slaves and evaluates them accordingly before sending them to the
host.
Select fixed focus and
parameterize one distance
configuration
see Table 6-8, Page 6-16
Forwarding distance
informations (optional)
Ö READING CONFIGURATION tab
Ö FOCUS CONTROL section
Ö AUTOFOCUS PARAMETERS button
–A
UTOFOCUS OPTIMIZATION PARAMETERS button
–O
BJECT HEIGHT PASSING IN OTS MODE section
–Active
Action Settings in CLV-Setup
Parameterize reading trigger Ö DEVICE CONFIGURATION tab
Ö READING TRIGGER SOURCE section
– OTS trigger
Table 6-15: Guide: Parameterizing reading trigger in the CLV490 for master/slave arrangement with
OTC400
Action Settings in CLV-Setup
1. Enable slave mode in
CLV490 for OTC400
(master)
Ö DEVICE CONFIGURATION tab
Ö TRACKING PARAMETERS button
Ö RELEASE POINTS section
– Object release point/End of reading field/Output data:
0 mm!
– Control box "Master/slave via OTC" active
2. Forwarding reading results to
the CAN interface
Ö HOST INTERFACE tab
Ö DESTINATION OF RESULT DATA STRINGS section
–CAN interface
3. Parameterize CAN interface
Ö CAN INTERFACE tab
Ö CAN INTERFACE FUNCTION section
– OTS slave
Ö CAN DATA RATE section
–500 kBit/s
Table 6-16: Guide: Parameterizing slave mode in the CLV490 for arrangement with OTC400
(master)
Action Settings in CLV-Setup
Table 6-14: Guide: Parameterizing focus control in CLV490 for master/slaves arrangement with
OTC400