Operating Instructions Chapter 5
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 5-27
Electrical installation
For connecting the switching outputs via the CDB420 or CDM490 Connection Module, see
the Operating Instructions for the "CDB420 Connection Module" (no. 8010001, German/
English) respectively the Operating Instructions for the "CDM490 Connection Module"
(no. 8010005, German/English).
Tip
The output function, pulse duration (timer), and polarity of the signals can be changed on
the D
EVICE CONFIGURATION tab in the "CLV-Setup" program.
¾ Click the R
ESULT OUTPUTS Parameter button.
Enter the values in the dialog box displayed.
Perform a download to the CLV490.
Recommendation ¾ To check the switching functions using a high-impedance digital voltmeter, connect a
load to the outputs to prevent incorrect voltage values/switching statuses from being
displayed.